SC
Electric & Gas Co. - Wateree
|
SC Electric & Gas Co. -
Wateree Station
142
Wateree Station Rd.
Eastover,
SC 29044
Richland
County
Air
Pollution Control Devices
|
| SO2: |
Wet limestone Flue gas desulfurization
(FGD){scrubbers} to be installed on both units to be completed September 2009. |
|
| NOx: |
Selective
Catalytic Reduction (SCR) {installed 2003}
and low-NOx
burners on both units. |
|
| Sources:
Title V air permit, govt.
agencies, industry, and/or media
reports |
|
Units -Year of
operation (power)
Unit 1 - 1970 (350Mw - 355Mw)
Unit 2 - 1971
(350Mw - 355Mw)
-
source: DOE
|
| Average NOx Rate (lb/mmBtu) |
Year
|
Unit 1
|
Unit 2
|
| 2008 |
0.30 |
0.28 |
| 2007 |
0.30 |
0.24 |
| 2006 |
0.33 |
0.22 |
| 2005 |
0.31 |
0.26 |
| 2004 |
0.33 |
0.28 |
| 2003 |
0.33 |
0.43 |
| 2002 |
0.45 |
0.43 |
| 2001 |
0.45 |
0.43 |
| 2000 |
0.46 |
0.41 |
| 1999 |
0.48 |
0.47 |
| 1998 |
0.53 |
0.58 |
| 1997 |
0.69 |
1.16 |
| 1996 |
1.11 |
1.14 |
| 1995 |
1.02 |
1.18 |
Nitrous Oxide, Sulfur
Dioxide, and Carbon Dioxide emissions
tons
per year - source: EPA data
|
|
Year
|
NOx
|
SO2
|
CO2
|
| 2008 |
6,223 |
35,471 |
4,495,524 |
| 2007 |
5,278 |
30,939 |
3,984,995 |
| 2006 |
5,821 |
32,797 |
4,173,114 |
| 2005 |
6,690 |
37,774 |
4,806,560 |
| 2004 |
7,185 |
39,421 |
4,723,669 |
| 2003 |
7,788 |
33,069 |
4,133,872 |
| 2002 |
9,380 |
36,378 |
4,217,174 |
| 2001 |
9,319 |
34,925 |
4,091,186 |
| 2000 |
9,269 |
31,184 |
4,206,893 |
| 1999 |
10,368 |
39,501 |
4,365,831 |
| 1998 |
11,116 |
36,387 |
4,019,790 |
| 1997 |
18,817 |
35,550 |
3,837,187 |
| 1996 |
23,657 |
39,533 |
4,095,814 |
| 1995 |
22,823 |
34,611 |
4,015,502 |
|
|
|