SC
Electric & Gas Co. - Canadys
|
SC Electric & Gas Co. -
Canadys Station
Hwy. 61 -
General Delivery
Canadys,
SC 29433
Colleton
County
Air
Pollution Control Devices
|
|
| NOx: |
low-NOx
burner and overfire air on all 3 units. |
|
| Sources:
Title V air permit, govt.
agencies, industry, and/or media
reports |
|
Units -Year of
operation (power)
Unit 1 - 1962 (115 Mw)
Unit 2 - 1964 (120
Mw)
Unit 3 - 1967 (180
Mw)
-
source: DOE
|
| Average NOx Rate (lb/mmBtu) |
Year
|
Unit 1
|
Unit 2
|
Unit 3
|
| 2008 |
0.40 |
0.37 |
0.35 |
| 2007 |
0.41 |
0.40 |
0.38 |
| 2006 |
0.39 |
0.43 |
0.36 |
| 2005 |
0.43 |
0.42 |
0.41 |
| 2004 |
0.39 |
0.40 |
0.42 |
| 2003 |
0.35 |
0.43 |
0.41 |
| 2002 |
0.36 |
0.45 |
0.38 |
| 2001 |
0.36 |
0.45 |
0.33 |
| 2000 |
0.40 |
0.41 |
0.38 |
| 1999 |
0.51 |
0.52 |
0.48 |
| 1998 |
0.57 |
0.53 |
0.42 |
| 1997 |
0.52 |
0.54 |
0.74 |
| 1996 |
0.52 |
0.56 |
0.86 |
| 1995 |
0.51 |
0.56 |
1.00 |
Nitrous Oxide, Sulfur
Dioxide, and Carbon Dioxide emissions
tons
per year - source: EPA data
|
|
Year
|
NOx
|
SO2
|
CO2
|
| 2008 |
4,036 |
17,966 |
2,239,996 |
| 2007 |
4,583 |
17,881 |
2,391,407 |
| 2006 |
4,998 |
22,984 |
2,639,835 |
| 2005 |
4,934 |
19,558 |
2,398,210 |
| 2004 |
5,946 |
27,088 |
2,996,641 |
| 2003 |
4,867 |
19,890 |
2,481,974 |
| 2002 |
4,398 |
18,592 |
2,254,691 |
| 2001 |
4,453 |
22,038 |
2,440,995 |
| 2000 |
4,565 |
18,666 |
2,362,176 |
| 1999 |
2,929 |
11,877 |
1,210,694 |
| 1998 |
4,487 |
17,345 |
1,850,561 |
| 1997 |
3,397 |
12,810 |
1,130,731 |
| 1996 |
4,481 |
13,229 |
1,367,386 |
| 1995 |
9,090 |
21,171 |
2,542,346 |
|
|
|